{"id":3176,"date":"2026-09-29T05:43:41","date_gmt":"2026-09-29T05:43:41","guid":{"rendered":"https:\/\/shop.autoboss.com\/?post_type=product&#038;p=3176"},"modified":"2026-10-09T08:20:30","modified_gmt":"2026-10-09T08:20:30","slug":"autool-em365-inverter-programming-power-supply-150a-battery-charger-jump-starter","status":"publish","type":"product","link":"https:\/\/autoboss.com\/de\/product\/autool-em365-inverter-programming-power-supply-150a-battery-charger-jump-starter\/","title":{"rendered":"AUTOOL EM365 150A ECU Programming Power Supply &#038; Battery Charger with 400A Forced Start"},"content":{"rendered":"<div class=\"abd-pd\" data-abd-version=\"1\">\n<header class=\"abd-hero\">\n<h3>Stable Battery Support for ECU Programming, Plus Charging and Start Assist<\/h3>\n<p class=\"abd-lead\">The EM365 holds vehicle voltage steady while a separate programming tool does the ECU work, and adds lead-acid charging, battery restoration, vehicle display power and 400 A momentary start support. It is for 12 V lead-acid type batteries only.<\/p>\n<ul class=\"abd-facts\">\n<li>Up to 150 A Programming<\/li>\n<li>Fixed 14 V or Adjustable<\/li>\n<li>20 A Charging<\/li>\n<li>400 A Start Assist<\/li>\n<li>5 Work Modes<\/li>\n<\/ul>\n<\/header>\n<section class=\"abd-sec\" id=\"abd-features\">\n<h4>Key Features<\/h4>\n<ol class=\"abd-features\">\n<li>\n<h5>Programming Power Supply<\/h5>\n<p>Set the voltage the vehicle procedure calls for, or choose fixed 14 V, and watch output voltage and current on the color screen.<\/p>\n<\/li>\n<li>\n<h5>Intelligent Charging<\/h5>\n<p>Adjusts voltage and current as charging progresses, with progress and completion shown on screen.<\/p>\n<\/li>\n<li>\n<h5>Battery-Type Settings<\/h5>\n<p>Standard lead-acid, AGM flat plate, AGM spiral and GEL; EFB through External Charging with the battery removed.<\/p>\n<\/li>\n<li>\n<h5>Vehicle Display Mode<\/h5>\n<p>Holds a float charge and raises output when loads discharge the battery, for showroom and display work.<\/p>\n<\/li>\n<li>\n<h5>Battery Restoration<\/h5>\n<p>A treatment mode for discharged or long-idle lead-acid batteries; results depend on condition and sulfation.<\/p>\n<\/li>\n<li>\n<h5>Forced Start<\/h5>\n<p>400 A \/ 12 V momentary starting support, guided by an on-screen prompt.<\/p>\n<\/li>\n<\/ol>\n<\/section>\n<section class=\"abd-sec\" id=\"abd-specs\">\n<h4>More Specifications<\/h4>\n<div class=\"abd-table-wrap\">\n<table class=\"abd-table abd-specs\">\n<tbody>\n<tr>\n<th scope=\"row\">Thermal recovery<\/th>\n<td>Full current returns when the unit cools to 50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Controls<\/th>\n<td>Physical buttons, adjustable screen brightness, selectable interface languages<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Cooling<\/th>\n<td>High-speed cooling fan<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/section>\n<section class=\"abd-sec\" id=\"abd-compare\">\n<h4>Model Comparison<\/h4>\n<div class=\"abd-table-wrap\">\n<table class=\"abd-table abd-compare\">\n<thead>\n<tr>\n<th scope=\"col\"><\/th>\n<th scope=\"col\">EM355<\/th>\n<th scope=\"col\" class=\"is-current\">EM365<\/th>\n<th scope=\"col\">EM385<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Maximum programming current<\/th>\n<td>120 A \/ approx. 3 min<\/td>\n<td class=\"is-current\">150 A \/ approx. 3 min<\/td>\n<td>150 A \/ approx. 3 min<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Work modes<\/th>\n<td>Programming, charging, restoration<\/td>\n<td class=\"is-current\">Programming, charging, restoration, vehicle display, forced start<\/td>\n<td>Programming, fast charging, restoration, vehicle display, forced start<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Lithium (LFP\/NCM) charging<\/th>\n<td>No<\/td>\n<td class=\"is-current\">No<\/td>\n<td>Yes, battery removed<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Separate adjustable supply<\/th>\n<td>No<\/td>\n<td class=\"is-current\">No<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Forced start<\/th>\n<td>No<\/td>\n<td class=\"is-current\">400 A \/ 12 V<\/td>\n<td>400 A \/ 12 V<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/section>\n<section class=\"abd-sec\" id=\"abd-box\">\n<h4>What&#8217;s in the Box<\/h4>\n<ul class=\"abd-box\">\n<li><b class=\"abd-qty\">1\u00d7<\/b>EM365 inverter programming power supply<\/li>\n<li><b class=\"abd-qty\">1\u00d7<\/b>Battery clamp output cable<\/li>\n<li><b class=\"abd-qty\">1\u00d7<\/b>AC power cable (plug type depends on version)<\/li>\n<li><b class=\"abd-qty\">1\u00d7<\/b>User manual<\/li>\n<\/ul>\n<figure class=\"abd-fig\"><img decoding=\"async\" src=\"https:\/\/autoboss.com\/wp-content\/uploads\/autool-catalog\/media\/b8150529a5a3ecd1dd6c996a.webp\" alt=\"AUTOOL EM365 power supply with retail box, battery clamp cable, AC power cable and user manual\" width=\"1200\" height=\"1200\" loading=\"lazy\"><figcaption>Main unit, cables, manual and retail box.<\/figcaption><\/figure>\n<\/section>\n<section class=\"abd-sec\" id=\"abd-use\">\n<h4>How to Use<\/h4>\n<ol class=\"abd-steps\">\n<li><b>Prepare the vehicle<\/b><span>Check the support voltage the procedure requires and make sure the 12 V battery is fully charged.<\/span><\/li>\n<li><b>Connect<\/b><span>Use a correct, grounded AC supply, keep vents clear, and clamp red to positive and black to negative.<\/span><\/li>\n<li><b>Select programming power<\/b><span>Choose Programmable Power Supply with the arrow keys, press OK and follow the prompts.<\/span><\/li>\n<li><b>Set the voltage<\/b><span>Pick Adjustable Mode and enter the required voltage, or Fixed Mode for 14 V.<\/span><\/li>\n<li><b>Run and monitor<\/b><span>Confirm the displayed voltage and current, then run the procedure with your programming tool until it completes.<\/span><\/li>\n<li><b>Stop output<\/b><span>Stop output before changing settings, switching tasks or disconnecting.<\/span><\/li>\n<\/ol>\n<p class=\"abd-note\">Menus, connections and safety: <a href=\"https:\/\/autoboss.com\/wp-content\/uploads\/autool-catalog\/media\/9454e902d11d279d36f5f5f0.pdf\" target=\"_blank\" rel=\"noopener\">EM365 user manual (PDF)<\/a>.<\/p>\n<\/section>\n<section class=\"abd-sec\" id=\"abd-notes\">\n<h4>Good to Know<\/h4>\n<div class=\"abd-notes\">\n<div class=\"abd-note-group is-caution\">\n<h5><span class=\"abd-tag\">Caution<\/span><\/h5>\n<ul>\n<li>Lithium batteries are not supported. EFB charging and Battery Restoration require the battery to be removed from the vehicle.<\/li>\n<li>Peak output lasts about 3 minutes before thermal limiting; confirm the mode, voltage and available current cover the full programming event.<\/li>\n<li>Connect clamps with correct polarity on clean, secure terminals before enabling output.<\/li>\n<\/ul>\n<\/div>\n<div class=\"abd-note-group is-care\">\n<h5><span class=\"abd-tag\">Care<\/span><\/h5>\n<ul>\n<li>Use in a dry, ventilated location with the vents clear.<\/li>\n<li>When charging ends, stop charging before removing the clamps.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"abd-sec\" id=\"abd-faq\">\n<h4>FAQ<\/h4>\n<details class=\"abd-faq\" name=\"abd-faq\">\n<summary>Does the EM365 program the ECU itself?<\/summary>\n<p>No. It supplies power during programming; use separate programming or diagnostic equipment for the ECU work.<\/p>\n<\/details>\n<details class=\"abd-faq\" name=\"abd-faq\">\n<summary>Why use programming mode instead of charging?<\/summary>\n<p>Programming mode holds the support voltage you choose; charging mode changes output as the battery charges.<\/p>\n<\/details>\n<details class=\"abd-faq\" name=\"abd-faq\">\n<summary>Which programming voltage should I select?<\/summary>\n<p>The voltage given in the vehicle procedure. Fixed Mode suits jobs that call for 14 V.<\/p>\n<\/details>\n<\/section>\n<\/div>","protected":false},"excerpt":{"rendered":"<ul>\n<li><strong>Adjustable \/ Fixed 14 V Programming:<\/strong> Select an adjustable programming voltage or fixed 14 V while monitoring voltage and current on the 2.8-inch color display.<\/li>\n<li><strong>150 A for Approximately 3 Minutes:<\/strong> Programming output reaches up to 150 A for approximately 3 minutes, with thermal protection reducing available current as the unit heats.<\/li>\n<li><strong>400 A \/ 12 V Start Support:<\/strong> Provide 400 A \/ 12 V momentary starting support for a compatible vehicle.<\/li>\n<li><strong>Up to 20 A Lead-Acid Charging:<\/strong> Charge standard lead-acid, AGM flat plate, AGM spiral, or GEL batteries at up to 20 A; EFB uses External Charging with the battery removed.<\/li>\n<li><strong>Up to 40 A Vehicle Display Support:<\/strong> Use the dedicated vehicle display setting for float-charge support, with up to 40 A available as battery discharge rises.<\/li>\n<\/ul>","protected":false},"featured_media":12244,"comment_status":"open","ping_status":"closed","template":"","meta":{"_gspb_post_css":""},"product_brand":[128],"product_cat":[64,62,71],"product_tag":[129],"class_list":["post-3176","product","type-product","status-publish","has-post-thumbnail","product_brand-autool","product_cat-car-battery-charger","product_cat-best-selling-products","product_cat-ecu-programming-tool","product_tag-autool","first","instock","shipping-taxable","purchasable","product-type-variable"],"_links":{"self":[{"href":"https:\/\/autoboss.com\/de\/wp-json\/wp\/v2\/product\/3176","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/autoboss.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/autoboss.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/autoboss.com\/de\/wp-json\/wp\/v2\/comments?post=3176"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/autoboss.com\/de\/wp-json\/wp\/v2\/media\/12244"}],"wp:attachment":[{"href":"https:\/\/autoboss.com\/de\/wp-json\/wp\/v2\/media?parent=3176"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/autoboss.com\/de\/wp-json\/wp\/v2\/product_brand?post=3176"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/autoboss.com\/de\/wp-json\/wp\/v2\/product_cat?post=3176"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/autoboss.com\/de\/wp-json\/wp\/v2\/product_tag?post=3176"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}