{"id":3299,"date":"2026-09-29T05:43:44","date_gmt":"2026-09-29T05:43:44","guid":{"rendered":"https:\/\/shop.autoboss.com\/?post_type=product&#038;p=3299"},"modified":"2026-10-09T08:20:31","modified_gmt":"2026-10-09T08:20:31","slug":"autool-lm130-smart-digital-manifold-kit","status":"publish","type":"product","link":"https:\/\/autoboss.com\/de\/product\/autool-lm130-smart-digital-manifold-kit\/","title":{"rendered":"AUTOOL LM130 Digital Manifold Gauge Kit with Refrigerant Sight Glass"},"content":{"rendered":"<div class=\"abd-pd\" data-abd-version=\"1\">\n<header class=\"abd-hero\">\n<h3>Live Pressure, Vacuum and Pressure-Hold Checks in One Digital Manifold<\/h3>\n<p class=\"abd-lead\">The LM130 shows live pressure and temperature for seven preset refrigerants, tracks vacuum during evacuation and monitors pressure retention, with a sight glass for watching refrigerant flow while charging. It does not identify refrigerant: confirm the system refrigerant before selecting a profile.<\/p>\n<ul class=\"abd-facts\">\n<li>0\u20136 MPa Gauge Pressure<\/li>\n<li>\u00b10.5% FS Accuracy<\/li>\n<li>7 Refrigerant Profiles<\/li>\n<li>2.8-Inch Backlit Display<\/li>\n<li>LM100 Data Link<\/li>\n<\/ul>\n<\/header>\n<section class=\"abd-sec\" id=\"abd-features\">\n<h4>Hauptmerkmale<\/h4>\n<ol class=\"abd-features\">\n<li>\n<h5>Temperature-Compensated Sensor<\/h5>\n<p>A built-in pressure sensor with temperature compensation supports accurate readings during A\/C service.<\/p>\n<\/li>\n<li>\n<h5>Live Refrigeration Readings<\/h5>\n<p>Pressure and temperature update in real time for the selected refrigerant profile.<\/p>\n<\/li>\n<li>\n<h5>Vacuum Monitoring<\/h5>\n<p>Follow relative-vacuum changes while the system is evacuated; an external vacuum-probe connection is supported.<\/p>\n<\/li>\n<li>\n<h5>Pressure-Retention Check<\/h5>\n<p>Shows pressure change during a hold test so you can tell whether system tightness needs further investigation.<\/p>\n<\/li>\n<li>\n<h5>Refrigerant Sight Glass<\/h5>\n<p>Watch refrigerant flow during charging. The window confirms visible flow only, not refrigerant identity or exact charge quantity.<\/p>\n<\/li>\n<li>\n<h5>LM100 Communication<\/h5>\n<p>An integrated microprocessor and communication interface sync measurement data with a separate LM100.<\/p>\n<\/li>\n<li>\n<h5>Service-Ready Build<\/h5>\n<p>Foldable hook, silicone side grip and dedicated controls for handheld or hanging use, with a multilayer nylon hose and brass connection hardware.<\/p>\n<\/li>\n<\/ol>\n<\/section>\n<section class=\"abd-sec\" id=\"abd-box\">\n<h4>What&#8217;s in the Box<\/h4>\n<ul class=\"abd-box\">\n<li>LM130 main unit<\/li>\n<li>Service hose and connections<\/li>\n<li>Printed user manual<\/li>\n<\/ul>\n<figure class=\"abd-fig\"><img decoding=\"async\" src=\"https:\/\/autoboss.com\/wp-content\/uploads\/autool-catalog\/media\/d8fc7d0e63e089f4d1df8768.webp\" alt=\"AUTOOL LM130 smart digital manifold kit with retail box, probe and user manual\" width=\"800\" height=\"800\" loading=\"lazy\"><figcaption>LM130 package.<\/figcaption><\/figure>\n<\/section>\n<section class=\"abd-sec\" id=\"abd-use\">\n<h4>Anwendung<\/h4>\n<ol class=\"abd-steps\">\n<li><b>Confirm refrigerant and ratings<\/b><span>Identify the refrigerant from reliable system information and compare system, instrument and hose working limits.<\/span><\/li>\n<li><b>Inspect and connect<\/b><span>Check fittings and hose condition, then attach suitable connectors per the manual and the refrigerant flow direction.<\/span><\/li>\n<li><b>Select profile and units<\/b><span>Choose the matching refrigerant profile and the pressure, vacuum and temperature units you need.<\/span><\/li>\n<li><b>Run the required mode<\/b><span>Monitor readings and charging flow, follow vacuum during evacuation, or record pressure change during a retention check.<\/span><\/li>\n<li><b>Review and follow up<\/b><span>Compare readings with the equipment procedure; if pressure does not hold, recheck connections and use an approved leak-location method.<\/span><\/li>\n<\/ol>\n<p class=\"abd-note\">Profiles, modes, LM100 link and troubleshooting: <a href=\"https:\/\/autoboss.com\/wp-content\/uploads\/autool-catalog\/media\/6c05977cf6e89c482811549a.pdf\" target=\"_blank\" rel=\"noopener\">LM130 user manual (PDF)<\/a><\/p>\n<\/section>\n<section class=\"abd-sec\" id=\"abd-notes\">\n<h4>Good to Know<\/h4>\n<div class=\"abd-notes\">\n<div class=\"abd-note-group is-caution\">\n<h5><span class=\"abd-tag\">Caution<\/span><\/h5>\n<ul>\n<li>The gauge does not identify unknown or mixed refrigerant; select only a refrigerant confirmed from the equipment label or service information.<\/li>\n<li>The 10 MPa overload figure and the 3000 PSI hose figure are limits, not working targets. Work to the lowest rating among the system, instrument and hose.<\/li>\n<li>Retention mode shows pressure change but does not locate a leak; finding the cause needs a separate approved test.<\/li>\n<\/ul>\n<\/div>\n<div class=\"abd-note-group is-care\">\n<h5><span class=\"abd-tag\">Care<\/span><\/h5>\n<ul>\n<li>Wear eye and hand protection and work in a well-ventilated area.<\/li>\n<li>Do not use or store the gauge in high heat, high humidity, flammable or explosive areas, or near strong electromagnetic fields.<\/li>\n<li>Do not modify the internal circuitry; replace the charging hose with a suitably rated one when required.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/section>\n<\/div>","protected":false},"excerpt":{"rendered":"<ul>\n<li><strong>Seven Refrigerant Profiles:<\/strong> Select R134a, R12, R410A, R407A, R404A, R22 or R502 to view live pressure and temperature readings.<\/li>\n<li><strong>0\u20136 MPa, \u00b10.5% FS:<\/strong> Measure gauge pressure from 0\u20136 MPa \/ 0\u201360 bar with \u00b10.5% full-scale accuracy.<\/li>\n<li><strong>Vacuum &amp; Hold Checks:<\/strong> Track relative vacuum during evacuation and monitor pressure change during retention checks to assess system tightness.<\/li>\n<li><strong>Visible Filling Flow:<\/strong> Watch refrigerant flow directly through the sight window while charging.<\/li>\n<li><strong>LM100 Data Link:<\/strong> Receives synchronized measurement data from the separate LM100 through its communication interface.<\/li>\n<\/ul>","protected":false},"featured_media":12267,"comment_status":"open","ping_status":"closed","template":"","meta":{"_gspb_post_css":""},"product_brand":[128],"product_cat":[109,62],"product_tag":[],"class_list":["post-3299","product","type-product","status-publish","has-post-thumbnail","product_brand-autool","product_cat-vehicle-ac-filling-and-maintenance-equipment","product_cat-best-selling-products","first","instock","shipping-taxable","purchasable","product-type-variable"],"_links":{"self":[{"href":"https:\/\/autoboss.com\/de\/wp-json\/wp\/v2\/product\/3299","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/autoboss.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/autoboss.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/autoboss.com\/de\/wp-json\/wp\/v2\/comments?post=3299"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/autoboss.com\/de\/wp-json\/wp\/v2\/media\/12267"}],"wp:attachment":[{"href":"https:\/\/autoboss.com\/de\/wp-json\/wp\/v2\/media?parent=3299"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/autoboss.com\/de\/wp-json\/wp\/v2\/product_brand?post=3299"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/autoboss.com\/de\/wp-json\/wp\/v2\/product_cat?post=3299"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/autoboss.com\/de\/wp-json\/wp\/v2\/product_tag?post=3299"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}