{"id":11153,"date":"2026-09-30T10:39:30","date_gmt":"2026-09-30T10:39:30","guid":{"rendered":"https:\/\/shop.autoboss.com\/?post_type=product&#038;p=11153"},"modified":"2026-10-09T05:51:59","modified_gmt":"2026-10-09T05:51:59","slug":"autool-lm120-digital-manifold-gauge-with-t1-t2-clamp-inputs","status":"publish","type":"product","link":"https:\/\/autoboss.com\/es\/product\/autool-lm120-digital-manifold-gauge-with-t1-t2-clamp-inputs\/","title":{"rendered":"AUTOOL LM120+ Digital Manifold Gauge with T1\/T2 Clamp Inputs"},"content":{"rendered":"<div class=\"abd-pd\" data-abd-version=\"1\">\n<header class=\"abd-hero\">\n<h3>Read High and Low Side Together, with Superheat and Subcooling Ready<\/h3>\n<p class=\"abd-lead\">The LM120+ digital manifold reads high- and low-side pressure at once and controls refrigerant flow with dedicated valves and a sight glass. Add compatible wired temperature clamps, sold separately, for T1\/T2 readings and SH\/SC calculations.<\/p>\n<ul class=\"abd-facts\">\n<li>Dual Pressure Readings<\/li>\n<li>T1\/T2 with Optional Clamps<\/li>\n<li>Superheat \/ Subcooling<\/li>\n<li>Vacuum &amp; Pressure Hold<\/li>\n<li>Charging Assist<\/li>\n<\/ul>\n<\/header>\n<section class=\"abd-sec\" id=\"abd-features\">\n<h4>Key Features<\/h4>\n<ol class=\"abd-features\">\n<li>\n<h5>Simultaneous High\/Low Pressure<\/h5>\n<p>Read both sides during A\/C and refrigeration service work.<\/p>\n<\/li>\n<li>\n<h5>Dual Temperature Inputs<\/h5>\n<p>Shows real-time T1 and T2 when compatible clamp probes are connected and fully seated on the pipes.<\/p>\n<\/li>\n<li>\n<h5>Superheat and Subcooling<\/h5>\n<p>Calculated after you select the correct refrigerant and attach stable temperature probes.<\/p>\n<\/li>\n<li>\n<h5>Relative-Vacuum Mode<\/h5>\n<p>Monitors pressure during an approved evacuation procedure, with leak time recording.<\/p>\n<\/li>\n<li>\n<h5>Timed Pressure Retention<\/h5>\n<p>Shows initial and current pressure, \u0394P and elapsed time for system-tightness checks.<\/p>\n<\/li>\n<li>\n<h5>Charging Assistance<\/h5>\n<p>Use the valves, sight glass and selected refrigerant data within the equipment&#8217;s procedure.<\/p>\n<\/li>\n<li>\n<h5>Handheld Construction<\/h5>\n<p>Engineering-plastic body with non-slip silicone, long-life valves and a foldable hook.<\/p>\n<\/li>\n<\/ol>\n<\/section>\n<section class=\"abd-sec\" id=\"abd-specs\">\n<h4>More Specifications<\/h4>\n<div class=\"abd-table-wrap\">\n<table class=\"abd-table abd-specs\">\n<tbody>\n<tr>\n<th scope=\"row\">Standard hose working pressure<\/th>\n<td>600 PSI (about 4.13 MPa)<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Standard hose limit pressure<\/th>\n<td>3000 PSI (about 20.68 MPa)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/section>\n<section class=\"abd-sec\" id=\"abd-compare\">\n<h4>Model Comparison<\/h4>\n<div class=\"abd-table-wrap\">\n<table class=\"abd-table abd-compare\">\n<thead>\n<tr>\n<th scope=\"col\"><\/th>\n<th scope=\"col\">LM120<\/th>\n<th scope=\"col\" class=\"is-current\">LM120+<\/th>\n<th scope=\"col\">LM150<\/th>\n<th scope=\"col\">LM160<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Focus<\/th>\n<td>Core digital manifold<\/td>\n<td class=\"is-current\">Three-color hose and clamp support<\/td>\n<td>Larger refrigerant database<\/td>\n<td>Program control, 8 languages<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature clamps<\/th>\n<td>Confirm package<\/td>\n<td class=\"is-current\">Supported, not included<\/td>\n<td>Two shown in package<\/td>\n<td>Two shown in package<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/section>\n<section class=\"abd-sec\" id=\"abd-box\">\n<h4>What&#8217;s in the Box<\/h4>\n<ul class=\"abd-box\">\n<li>LM120+ main unit<\/li>\n<li>Red, blue and yellow hose set<\/li>\n<li>Adapters and couplers (exact items depend on the package)<\/li>\n<li>Storage case<\/li>\n<li>User manual<\/li>\n<\/ul>\n<\/section>\n<section class=\"abd-sec\" id=\"abd-use\">\n<h4>How to Use<\/h4>\n<ol class=\"abd-steps\">\n<li><b>Identify the refrigerant<\/b><span>Select the refrigerant confirmed by the vehicle or equipment information.<\/span><\/li>\n<li><b>Check kit and ratings<\/b><span>Confirm probes, batteries and the separate gauge, hose and system ratings.<\/span><\/li>\n<li><b>Inspect, zero and connect<\/b><span>Close the valves, inspect fittings and hoses, choose refrigerant and units, zero if needed, then connect.<\/span><\/li>\n<li><b>Measure or service<\/b><span>Use pressure, vacuum or retention mode; attach both clamps firmly for T1\/T2 or SH\/SC.<\/span><\/li>\n<li><b>Close and review<\/b><span>Follow the manual&#8217;s valve and disconnect sequence and interpret results against the system specification.<\/span><\/li>\n<\/ol>\n<p class=\"abd-note\">Specifications, refrigerant filling, vacuum and leak testing: <a href=\"https:\/\/autoboss.com\/wp-content\/uploads\/autool-catalog\/media\/cf1714f1ff21c490e9a37953.pdf\" target=\"_blank\" rel=\"noopener\">LM120 \/ LM120+ user manual (PDF)<\/a><\/p>\n<\/section>\n<section class=\"abd-sec\" id=\"abd-notes\">\n<h4>Good to Know<\/h4>\n<div class=\"abd-notes\">\n<div class=\"abd-note-group is-caution\">\n<h5><span class=\"abd-tag\">Caution<\/span><\/h5>\n<ul>\n<li>Temperature clamps are not included; T1\/T2 and SH\/SC need compatible wired clamps bought separately.<\/li>\n<li>Work within the lowest rating of the system, gauge and hose; the hose working pressure is lower than the gauge limit.<\/li>\n<li>Replace damaged hoses, seals and fittings before connecting.<\/li>\n<li>The gauge does not identify refrigerant or locate leaks; use a reliable identification and an approved leak-location method.<\/li>\n<li>Batteries may not be included; confirm for your order.<\/li>\n<\/ul>\n<\/div>\n<div class=\"abd-note-group is-care\">\n<h5><span class=\"abd-tag\">Care<\/span><\/h5>\n<ul>\n<li>Wear protective equipment and work in a well-ventilated area.<\/li>\n<li>Keep the instrument away from hot, humid, flammable, explosive or strong-EMF environments, and do not modify its circuit.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/section>\n<\/div>","protected":false},"excerpt":{"rendered":"<ul>\n<li><strong>Dual-Side Pressure Control:<\/strong> Read high- and low-side gauge pressure together, using dedicated valves, a sight window, and standard 1\/4-inch connections.<\/li>\n<li><strong>Probe-Ready SH\/SC:<\/strong> Display T1\/T2 and calculate SH\/SC when compatible wired clamps are connected and the correct refrigerant is selected; clamps are sold separately.<\/li>\n<li><strong>Vacuum, Hold + Charge Modes:<\/strong> Supports relative-vacuum monitoring, timed pressure-retention checks, and refrigerant-charging assistance.<\/li>\n<li><strong>Backlit Multi-Unit Display:<\/strong> Switch among five pressure units and Celsius or Fahrenheit on the large backlit LCD.<\/li>\n<\/ul>","protected":false},"featured_media":12377,"comment_status":"open","ping_status":"closed","template":"","meta":{"_gspb_post_css":""},"product_brand":[128],"product_cat":[109],"product_tag":[],"class_list":["post-11153","product","type-product","status-publish","has-post-thumbnail","product_brand-autool","product_cat-vehicle-ac-filling-and-maintenance-equipment","first","instock","shipping-taxable","purchasable","product-type-variable"],"_links":{"self":[{"href":"https:\/\/autoboss.com\/es\/wp-json\/wp\/v2\/product\/11153","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/autoboss.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/autoboss.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/autoboss.com\/es\/wp-json\/wp\/v2\/comments?post=11153"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/autoboss.com\/es\/wp-json\/wp\/v2\/media\/12377"}],"wp:attachment":[{"href":"https:\/\/autoboss.com\/es\/wp-json\/wp\/v2\/media?parent=11153"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/autoboss.com\/es\/wp-json\/wp\/v2\/product_brand?post=11153"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/autoboss.com\/es\/wp-json\/wp\/v2\/product_cat?post=11153"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/autoboss.com\/es\/wp-json\/wp\/v2\/product_tag?post=11153"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}