{"id":3310,"date":"2026-09-29T05:43:44","date_gmt":"2026-09-29T05:43:44","guid":{"rendered":"https:\/\/shop.autoboss.com\/?post_type=product&#038;p=3310"},"modified":"2026-10-09T08:25:05","modified_gmt":"2026-10-09T08:25:05","slug":"autool-lm707-refrigerant-recovery-machine","status":"publish","type":"product","link":"https:\/\/autoboss.com\/es\/product\/autool-lm707-refrigerant-recovery-machine\/","title":{"rendered":"AUTOOL LM707 R-134a A\/C Recovery Machine with Auto Vacuum &#038; Recharge"},"content":{"rendered":"<div class=\"abd-pd\" data-abd-version=\"1\">\n<header class=\"abd-hero\">\n<h3>Recover, Evacuate and Recharge R134a Systems From One Station<\/h3>\n<p class=\"abd-lead\">Preset the job values on the LM707 and it runs recovery, evacuation and recharge in sequence while you monitor the prompts. A built-in filter and separator clean recovered refrigerant for permitted reuse. R134a only; the station does not identify refrigerant.<\/p>\n<ul class=\"abd-facts\">\n<li>R134a Only<\/li>\n<li>Automatic Sequence<\/li>\n<li>\u00b110 g Scale<\/li>\n<li>2 \u00d7 350 mL Oil Bottles<\/li>\n<li>12 kg Internal Tank<\/li>\n<\/ul>\n<\/header>\n<section class=\"abd-sec\" id=\"abd-features\">\n<h4>Key Features<\/h4>\n<ol class=\"abd-features\">\n<li>\n<h5>Automatic Recovery, Vacuum and Recharge<\/h5>\n<p>Enter the recovery, evacuation and recharge values, then let the station run the steps in order while you check prompts and final results.<\/p>\n<\/li>\n<li>\n<h5>Weighed Refrigerant Quantities<\/h5>\n<p>The built-in electronic scale measures refrigerant weight during recovery and refilling.<\/p>\n<\/li>\n<li>\n<h5>Recovered-Refrigerant Cleaning<\/h5>\n<p>A filter and separator clean recovered R134a for permitted reuse, and internal circulation purification keeps the stored refrigerant in condition.<\/p>\n<\/li>\n<li>\n<h5>Separate New and Used Oil<\/h5>\n<p>One bottle for new oil and one for used oil keep compressor-oil draining and manual refilling apart.<\/p>\n<\/li>\n<li>\n<h5>Onboard Working Tank<\/h5>\n<p>Stores R134a so the station can service several vehicles in a row without changing cylinders.<\/p>\n<\/li>\n<li>\n<h5>Centralized Controls<\/h5>\n<p>Display, keypad and dedicated pressure gauges keep setup and system readings in one place; the interface is available in six languages.<\/p>\n<\/li>\n<\/ol>\n<\/section>\n<section class=\"abd-sec\" id=\"abd-specs\">\n<h4>More Specifications<\/h4>\n<div class=\"abd-table-wrap\">\n<table class=\"abd-table abd-specs\">\n<tbody>\n<tr>\n<th scope=\"row\">Refrigerant identification<\/th>\n<td>Not supported; identify and isolate unknown or contaminated refrigerant before connecting<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leak check<\/th>\n<td>Vacuum\/pressure-hold check only; does not locate a leak<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Filling port selection<\/th>\n<td>Not available (HP\/LP\/HP+LP selection is on the LM708 and LM806)<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Data printing and database<\/th>\n<td>Not available<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/section>\n<section class=\"abd-sec\" id=\"abd-compare\">\n<h4>Model Comparison<\/h4>\n<div class=\"abd-table-wrap\">\n<table class=\"abd-table abd-compare\">\n<thead>\n<tr>\n<th scope=\"col\"><\/th>\n<th scope=\"col\" class=\"is-current\">LM707<\/th>\n<th scope=\"col\">LM708<\/th>\n<th scope=\"col\">LM806<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Refrigerant<\/th>\n<td class=\"is-current\">R-134a<\/td>\n<td>HFO-1234yf \/ R-134a<\/td>\n<td>R-134a<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Display<\/th>\n<td class=\"is-current\">5-inch display<\/td>\n<td>7-inch touch screen<\/td>\n<td>10.1-inch touch screen<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Electronic scales<\/th>\n<td class=\"is-current\">1<\/td>\n<td>5<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Oil adding<\/th>\n<td class=\"is-current\">Manual<\/td>\n<td>Automatic<\/td>\n<td>Automatic<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Oil bottles<\/th>\n<td class=\"is-current\">2 \u00d7 350 mL<\/td>\n<td>3 \u00d7 350 mL<\/td>\n<td>3 \u00d7 500 mL<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Tank capacity<\/th>\n<td class=\"is-current\">12 kg<\/td>\n<td>15 kg (maximum fill 10 kg)<\/td>\n<td>18 kg (maximum fill 12 kg)<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Printing, database, operation records<\/th>\n<td class=\"is-current\">No<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Pipeline flushing<\/th>\n<td class=\"is-current\">No<\/td>\n<td>No<\/td>\n<td>Yes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/section>\n<section class=\"abd-sec\" id=\"abd-box\">\n<h4>What&#8217;s in the Box<\/h4>\n<ul class=\"abd-box\">\n<li>LM707 main unit with onboard oil bottles and tank<\/li>\n<li>Red and blue service hoses<\/li>\n<li>High- and low-side quick couplers<\/li>\n<li>Regional power cable<\/li>\n<li>User manual<\/li>\n<\/ul>\n<figure class=\"abd-fig\"><img decoding=\"async\" src=\"https:\/\/autoboss.com\/wp-content\/uploads\/autool-catalog\/media\/cc71a644dd4115dd61b800ee.webp\" alt=\"AUTOOL LM707 recovery machine with high and low quick couplers, red and blue service hoses, power cable and user manual\" width=\"1200\" height=\"1200\" loading=\"lazy\"><figcaption>LM707 package contents. Confirm the plug type against the unit nameplate.<\/figcaption><\/figure>\n<\/section>\n<section class=\"abd-sec\" id=\"abd-use\">\n<h4>How to Use<\/h4>\n<ol class=\"abd-steps\">\n<li><b>Verify refrigerant and vehicle data<\/b><span>Confirm the vehicle uses R134a and look up the correct refrigerant charge and oil information.<\/span><\/li>\n<li><b>Inspect machine and tank<\/b><span>Check hoses and couplers, oil and pump-oil levels, filter status, tank safety and working refrigerant quantity.<\/span><\/li>\n<li><b>Connect with the engine off<\/b><span>Attach the high- and low-side couplers securely and keep hoses clear of heat and moving parts.<\/span><\/li>\n<li><b>Preset and run<\/b><span>Enter the recovery, evacuation and recharge values, then monitor the automatic sequence.<\/span><\/li>\n<li><b>Verify and disconnect<\/b><span>Review recovered and charged amounts, pressures and A\/C operation, then close and disconnect safely.<\/span><\/li>\n<\/ol>\n<p class=\"abd-note\">Setup, oil handling, filter service and troubleshooting: <a href=\"https:\/\/autoboss.com\/wp-content\/uploads\/autool-catalog\/media\/4a22b7df76682228919c81ac.pdf\" target=\"_blank\" rel=\"noopener\">LM707 user manual (PDF)<\/a>.<\/p>\n<\/section>\n<section class=\"abd-sec\" id=\"abd-notes\">\n<h4>Good to Know<\/h4>\n<div class=\"abd-notes\">\n<div class=\"abd-note-group is-caution\">\n<h5><span class=\"abd-tag\">Caution<\/span><\/h5>\n<ul>\n<li>Never connect the LM707 to HFO-1234yf, mixed, unidentified or any other refrigerant.<\/li>\n<li>Never fill the internal tank above 80% of its capacity; the margin guards against extra pressure from external factors.<\/li>\n<li>Keep at least 3 kg of refrigerant in the tank, or recharging may not be possible.<\/li>\n<li>Start recovery no more than 10 times per hour; frequent starts can damage the compressor.<\/li>\n<li>Do not use compressed air to pressure- or leak-test the station or the vehicle A\/C circuit.<\/li>\n<li>Use grounded power that matches the unit nameplate, and keep the station away from open flames and hot objects.<\/li>\n<\/ul>\n<\/div>\n<div class=\"abd-note-group is-care\">\n<h5><span class=\"abd-tag\">Care<\/span><\/h5>\n<ul>\n<li>Replace the filter after 100 kg of recovered refrigerant, following the device prompt.<\/li>\n<li>Service the vacuum-pump oil when the 600-minute reminder appears, or sooner if it turns cloudy or contaminated.<\/li>\n<li>Run circulation purification about once a month.<\/li>\n<li>Add compressor oil according to the amount discharged; avoid overfilling.<\/li>\n<li>Do not modify the pressure-reducing valve or system settings.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/section>\n<\/div>","protected":false},"excerpt":{"rendered":"<ul>\n<li><strong>Automatic R134a Service:<\/strong> Preset job parameters for automatic R134a recovery, evacuation and measured recharge, with prompts and final results.<\/li>\n<li><strong>\u00b110 g Refrigerant Scale:<\/strong> A built-in electronic scale with \u00b110 g accuracy tracks refrigerant recovery and charge quantities.<\/li>\n<li><strong>Recovered R134a Cleaning:<\/strong> A built-in filter and separator clean recovered R134a for permitted reuse.<\/li>\n<li><strong>Separate Oil Handling:<\/strong> Use dedicated 350 ml bottles to keep new and used oil separate.<\/li>\n<\/ul>","protected":false},"featured_media":12269,"comment_status":"open","ping_status":"closed","template":"","meta":{"_gspb_post_css":""},"product_brand":[128],"product_cat":[109,62],"product_tag":[129],"class_list":["post-3310","product","type-product","status-publish","has-post-thumbnail","product_brand-autool","product_cat-vehicle-ac-filling-and-maintenance-equipment","product_cat-best-selling-products","product_tag-autool","first","instock","shipping-taxable","purchasable","product-type-variable"],"_links":{"self":[{"href":"https:\/\/autoboss.com\/es\/wp-json\/wp\/v2\/product\/3310","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/autoboss.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/autoboss.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/autoboss.com\/es\/wp-json\/wp\/v2\/comments?post=3310"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/autoboss.com\/es\/wp-json\/wp\/v2\/media\/12269"}],"wp:attachment":[{"href":"https:\/\/autoboss.com\/es\/wp-json\/wp\/v2\/media?parent=3310"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/autoboss.com\/es\/wp-json\/wp\/v2\/product_brand?post=3310"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/autoboss.com\/es\/wp-json\/wp\/v2\/product_cat?post=3310"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/autoboss.com\/es\/wp-json\/wp\/v2\/product_tag?post=3310"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}