Specifications

BrandAUTOOL
SKUAB-SHOPIFY-10029345112350
Pressure Range0–6 MPa / 0–60 bar; vacuum -101–0 kPa
Accuracy±0.5% FS
Refrigerants7 types: R134a, R12, R410A, R407A, R404A, R22, R502
ModesReal-time pressure/temperature, vacuum, pressure hold
Sight GlassRefrigerant charging sight glass
Data LinkCan connect to LM100 for data sync
Display2.8-inch backlit, approx. 0.5 second response
Unitspsi/bar/MPa; micron/Torr/mbar; °C/°F
HosesWorking pressure 600 PSI, limit 3000 PSI
Overload Limit10 MPa / 100 bar
Auto Power Off20 minutes
CompatibilityAutomotive A/C and refrigeration systems (refrigerant must be known)

Details

Live Pressure, Vacuum and Pressure-Hold Checks in One Digital Manifold

The LM130 shows live pressure and temperature for seven preset refrigerants, tracks vacuum during evacuation and monitors pressure retention, with a sight glass for watching refrigerant flow while charging. It does not identify refrigerant: confirm the system refrigerant before selecting a profile.

  • 0–6 MPa Gauge Pressure
  • ±0.5% FS Accuracy
  • 7 Refrigerant Profiles
  • 2.8-Inch Backlit Display
  • LM100 Data Link

Key Features

  1. Temperature-Compensated Sensor

    A built-in pressure sensor with temperature compensation supports accurate readings during A/C service.

  2. Live Refrigeration Readings

    Pressure and temperature update in real time for the selected refrigerant profile.

  3. Vacuum Monitoring

    Follow relative-vacuum changes while the system is evacuated; an external vacuum-probe connection is supported.

  4. Pressure-Retention Check

    Shows pressure change during a hold test so you can tell whether system tightness needs further investigation.

  5. Refrigerant Sight Glass

    Watch refrigerant flow during charging. The window confirms visible flow only, not refrigerant identity or exact charge quantity.

  6. LM100 Communication

    An integrated microprocessor and communication interface sync measurement data with a separate LM100.

  7. Service-Ready Build

    Foldable hook, silicone side grip and dedicated controls for handheld or hanging use, with a multilayer nylon hose and brass connection hardware.

What’s in the Box

  • LM130 main unit
  • Service hose and connections
  • Printed user manual
AUTOOL LM130 smart digital manifold kit with retail box, probe and user manual
LM130 package.

How to Use

  1. Confirm refrigerant and ratingsIdentify the refrigerant from reliable system information and compare system, instrument and hose working limits.
  2. Inspect and connectCheck fittings and hose condition, then attach suitable connectors per the manual and the refrigerant flow direction.
  3. Select profile and unitsChoose the matching refrigerant profile and the pressure, vacuum and temperature units you need.
  4. Run the required modeMonitor readings and charging flow, follow vacuum during evacuation, or record pressure change during a retention check.
  5. Review and follow upCompare readings with the equipment procedure; if pressure does not hold, recheck connections and use an approved leak-location method.

Profiles, modes, LM100 link and troubleshooting: LM130 user manual (PDF)

Good to Know

Caution
  • The gauge does not identify unknown or mixed refrigerant; select only a refrigerant confirmed from the equipment label or service information.
  • The 10 MPa overload figure and the 3000 PSI hose figure are limits, not working targets. Work to the lowest rating among the system, instrument and hose.
  • Retention mode shows pressure change but does not locate a leak; finding the cause needs a separate approved test.
Care
  • Wear eye and hand protection and work in a well-ventilated area.
  • Do not use or store the gauge in high heat, high humidity, flammable or explosive areas, or near strong electromagnetic fields.
  • Do not modify the internal circuitry; replace the charging hose with a suitably rated one when required.

You may also like

Select specifications

Delivery

Shipping calculated at checkout

Warehouses

  • CN Warehouse
  • DE Warehouse
  • UK Warehouse
  • US Warehouse

Choose the warehouse in the specifications.

Service

  • Secure checkout

    Payments are processed over an encrypted connection.

  • After-sales support

    Contact us for installation or usage questions.

Specifications

Brand
AUTOOL
SKU
AB-SHOPIFY-10029345112350
Pressure Range
0–6 MPa / 0–60 bar; vacuum -101–0 kPa
Accuracy
±0.5% FS
Refrigerants
7 types: R134a, R12, R410A, R407A, R404A, R22, R502
Modes
Real-time pressure/temperature, vacuum, pressure hold
Sight Glass
Refrigerant charging sight glass
Data Link
Can connect to LM100 for data sync
Display
2.8-inch backlit, approx. 0.5 second response
Units
psi/bar/MPa; micron/Torr/mbar; °C/°F
Hoses
Working pressure 600 PSI, limit 3000 PSI
Overload Limit
10 MPa / 100 bar
Auto Power Off
20 minutes
Compatibility
Automotive A/C and refrigeration systems (refrigerant must be known)

Write a review

AUTOOL LM130 Digital Manifold Gauge Kit with Refrigerant Sight Glass
Overall rating *
What stood out?optional, up to 3
Add photos0 / 5
JPG, PNG or WebP, up to 5 MB each.

Reviews are checked before they appear. Verified Purchase is added automatically when your email matches an order.

AUTOOL LM130 Smart Digital Manifold Kit with Filling Window
AUTOOL LM130 Digital Manifold Gauge Kit with Refrigerant Sight Glass

US$135.00

Select options This product has multiple variants. The options may be chosen on the product page