Read Pressure and Temperature, and Get Superheat and Subcooling
The L205 digital manifold shows pressure and temperature in real time, calculates subcooling and superheat from its built-in refrigerant database, and measures vacuum percentage and pressure-hold leaks for A/C and refrigeration work.
- Oververhitting / onderkoeling
- Vacuümpercentage
- Lektest door druk vast te houden
- Weergave van meerdere eenheden
- Metal Fittings
Key Features
-
Druk en temperatuur samen
Real-time vacuum and pressure values with automatic pressure-unit and Celsius/Fahrenheit conversion.
-
Koelmiddelendatabase
Built-in refrigerant pressure–evaporation temperature data lets the gauge calculate subcooling and superheat for direct reading.
-
Vacuüm- en lektests
Shows vacuum percentage and runs pressure leakage tests that record leak time and rate.
-
Metalen interface
Durable, corrosion-resistant metal fittings.
-
Gebruik in meerdere situaties
Air conditioning installation and maintenance, refrigerator repair, cold storage inspection and automotive A/C service.
Highlights

Beide zijden tegelijk
Evaporation and condensation temperatures with low- and high-side pressures on one screen.

Vacuümmeting
Vacuum pressure and vacuum percentage in real time while evacuating the system.
Meer specificaties
| Pressure type | Gauge pressure |
|---|---|
| Standard hose maximum operating pressure | 600 PSI (circa 4.13 MPa, 41.3 bar) |
| Grensdruk van de standaardslang | 3000 PSI (circa 20.68 MPa, 206.8 bar) |
Modelvergelijking
| L202 | L205 | L302 | L505 | |
|---|---|---|---|---|
| Pressure units | kPa, bar, psi, inHg, kgf/cm² | kPa, MPa, bar, inHg, psi | kPa, bar, psi, inHg, kgf/cm² | kPa, bar, psi, inHg, kgf/cm² |
| Eenheden voor vacuümgraad | No | No | No | hPa/mbar/Torr |
| Kijkvenster voor koudemiddel | No | No | No | Ja |
| Druklektest | Ja | Ja | Ja | Ja |
| Product size | 150 × 90 × 60 mm | 165 × 113 × 60 mm | 170 × 170 × 60 mm | 210 × 110 × 40 mm |
Inhoud van de doos
- L205-hoofdeenheid
- Storage bag
- User manual

Instelling en bediening: L205-gebruikershandleiding (PDF).
Good to Know
Let op
- Confirm the rated pressure of the equipment before testing, and do not use the gauge beyond its range.
- Do not use or store the instrument in high-temperature, high-humidity, flammable, explosive or strong electromagnetic environments.
- Wijzig het interne circuit niet.
- Wear suitable protective equipment and work in a well-ventilated area to avoid inhaling toxic gases.