Specifications

BrandAUTOOL
SKUAUTOOL-25215
Output<15 psi, <6 L/min
Air SupplyBuilt-in air pump
MonitoringExternal pressure gauge + flow meter, flow adjustment knob
Smoke TimeApprox. 5 seconds
Adapters23 intake adapters, plus bladder adapter and cone adapter
Power SupplyDC 12V battery, rated 65W
Protection>75°C overheat shutoff, low-temperature protection; fault indicator
Smoke FluidLiquid paraffin or baby oil 10–15 mL (not included)
Weight1.7 kg
Dimensions145 × 80 × 200 mm
CompatibilityLow-pressure leak testing of EVAP, fuel tank, intake/exhaust, engine/body seals, pipe joints; AC only via indirect check of isolated sections

Details

Smoke Leak Testing With Pressure and Flow Feedback, No Shop Air Needed

The SDT203’s built-in pump supplies the test air while a pressure gauge and flow meter show how the sealed line responds; then follow the escaping smoke to the leak. It runs from a 12 V vehicle battery, and testing oil is not included.

  • Built-In Air Pump
  • Pressure Gauge + Flow Meter
  • Flow Adjustment Knob
  • 23 Intake Adapters
  • About 5 s Smoke

Key Features

  1. Pressure Gauge

    Shows whether the test line holds pressure: stable or rising pressure suggests a good seal, falling pressure may indicate a leak.

  2. Flow Meter and Knob

    Watch airflow changes during the test and adjust output for each line; the knob controls flow, not pressure.

  3. Built-In Air Pump

    No compressor or shop air is needed to run a test.

  4. EVAP and Fuel Tank Checks

    Test EVAP systems and fuel tanks with adapters that match the vehicle test port.

  5. Intake, Exhaust and Sealing Checks

    Find leaks in intake and exhaust systems, engine and body sealing areas, and line fittings where smoke escapes.

  6. Hook Mounting

    The compact body hangs from its hook near the test area and stores easily.

Model Comparison

SDT203 SDT103 SDT205S
Air source Built-in pump External Built-in pump
Rated output pressure <15 psi 3.2 kPa (0.46 psi) <15 psi
Rated output flow <6 L/min >10 L/min <6 L/min
Modes Smoke Smoke Air + Smoke
Pressure gauge Yes No Yes
Oil drain valve No No Yes
Main unit weight 1.7 kg 1.15 kg 3.2 kg

What’s in the Box

  • SDT203 smoke leak detector
  • 12 V battery clamp cable
  • Smoke hose
  • 23 intake adapters
  • Cone, airbag and straight adapters
  • Hook and funnel
  • User manual

Testing oil is not included; use liquid paraffin or baby oil.

How to Use

  1. Add testing oilFill through the oil refill port; drain some out if overfilled.
  2. Mount and open airflowFit the hook, position the unit near the test area and gently open the flow control valve.
  3. Connect the smoke hoseWith the ignition off, connect the hose between the smoke outlet and the line under test.
  4. Connect powerRed clamp to positive (+), black clamp to negative (−) on a fully charged 12 V battery.
  5. Generate smokePress the Smoke Mode switch, let the line fill and inspect for escaping smoke; after stopping, let the unit purge residual smoke.
  6. Confirm and retestCheck the escape path against the system layout, repair the leak and repeat the same test.

Pressure and flow monitoring, adapter sealing and test-oil handling: SDT203 user manual (PDF).

Good to Know

Caution
  • Low-pressure tester: it cannot pressure-test an automotive A/C system; use smoke only as an indirect aid on an isolated A/C line section when the service procedure permits.
  • Do not run continuously for more than 8 minutes; let the unit cool before restarting.
  • Never refill testing oil while running, and do not use water or sticky liquids as testing oil.
  • Keep smoke away from headlights and any component where smoke testing is not permitted.
  • Keep the unit away from water and liquids, and avoid touching the metal housing when hot.
Care
  • Refill only when the smoke becomes thin: drain the old oil first and add no more than 15 mL at a time.

You may also like

Select specifications

Delivery

Shipping calculated at checkout

Warehouses

  • CN Warehouse
  • DE Warehouse
  • UK Warehouse
  • US Warehouse

Choose the warehouse in the specifications.

Service

  • Secure checkout

    Payments are processed over an encrypted connection.

  • After-sales support

    Contact us for installation or usage questions.

Specifications

Brand
AUTOOL
SKU
AUTOOL-25215
Output
<15 psi, <6 L/min
Air Supply
Built-in air pump
Monitoring
External pressure gauge + flow meter, flow adjustment knob
Smoke Time
Approx. 5 seconds
Adapters
23 intake adapters, plus bladder adapter and cone adapter
Power Supply
DC 12V battery, rated 65W
Protection
>75°C overheat shutoff, low-temperature protection; fault indicator
Smoke Fluid
Liquid paraffin or baby oil 10–15 mL (not included)
Weight
1.7 kg
Dimensions
145 × 80 × 200 mm
Compatibility
Low-pressure leak testing of EVAP, fuel tank, intake/exhaust, engine/body seals, pipe joints; AC only via indirect check of isolated sections

Write a review

AUTOOL SDT203 Automotive Smoke Leak Detector with Pressure Gauge & Flow Meter
Overall rating *
What stood out?optional, up to 3
Add photos0 / 5
JPG, PNG or WebP, up to 5 MB each.

Reviews are checked before they appear. Verified Purchase is added automatically when your email matches an order.

AUTOOL SDT203 Automotive Smoke Leak Detector with Pressure Gauge & Flow Meter
AUTOOL SDT203 Automotive Smoke Leak Detector with Pressure Gauge & Flow Meter

US$159.00

Ausführung wählen Dieses Produkt weist mehrere Varianten auf. Die Optionen können auf der Produktseite gewählt werden