Specifications

BrandAUTOOL
SKUAUTOOL-80430
Dimensionsn. v.
Applicable RefrigerantsR134a only
Recovery Speed>350 g/min
Charging Speed>800 g/min
Vacuum Pump Flow Rate60 L/min
Display10.1-inch touch screen
Electronic Scales4: working tank ±10 g; PAG/POE/waste oil ±5 g
Tankvolumen18 kg working tank (not exceeding 80% of effective capacity)
Oil Bottles3 (2 new oil + 1 waste oil), automatic oil injection
FunktionenRecovery, recycling, vacuum, charging, line flushing, pressure hold check
DatabaseEditable vehicle database for 61 brands
RecordsVIN entry, thermal printing, operation record query
Sprachen5 languages
KompatibilitätR134a gasoline, hybrid and electric vehicles (per OEM refrigerant oil and high-voltage procedures)
Software-UpdatesEditable 61-brand database; 5 languages

Details

Recover, Recycle, Flush and Recharge R134a From One Guided Station

The LM806 runs a configured R134a sequence — recovery, recycling, evacuation and recharge — once the technician confirms the refrigerant and enters verified values, and adds line flushing and printed service records. R134a only; there is no built-in refrigerant identifier.

  • R134a Only
  • >350 g/min Recovery
  • >800 g/min Charging
  • 4 Electronic Scales
  • Line Flushing

Hauptmerkmale

  1. Four-Stage Refrigerant Processing

    Separates used oil, filters and dries recovered refrigerant, manages non-condensable gas and stores the processed R134a in the working tank.

  2. Separate Fluid Scales

    The working tank, PAG oil, POE oil and used oil are weighed at their own positions; the stated accuracies are scale specifications, not whole-machine accuracy.

  3. PAG and POE Oil Paths

    Two new-oil positions plus used-oil measurement support vehicle-specific oil handling, including compatible hybrid and EV work.

  4. Line Flushing Without Disassembly

    Circulates R134a through permitted A/C lines; remove, bypass or replace excluded components as the OEM procedure requires.

  5. Vehicle Data and Service Records

    The editable database gives a starting point for charge values; enter VIN and job details and print the operation record.

  6. Pressure Review

    High- and low-side pressures are shown for connection checks and post-service review.

  7. Serviceable Design

    Rear service access for maintenance; filter and vacuum-pump oil service are prompted by the machine.

More Specifications

Refrigerant identification Not built in; identify and isolate refrigerant before connecting
Leak check Vacuum-hold check only; does not locate a leak
Power supply Regional version; confirm the unit nameplate (do not assume both 110 V and 220 V)

Model Comparison

LM707 LM708 LM806
Refrigerant R-134a HFO-1234yf / R-134a R-134a
Display 5-inch display 7-inch touch screen 10.1-inch touch screen
Sprachen 6 4 5
Electronic scales 1 5 4
Oil adding Manual Automatic Automatic
Pipeline flushing No No Yes
Printing, database, operation records No Yes Yes

What’s in the Box

  • 1×LM806 main unit
  • 1×Hose set: 3 m red and blue high/low-pressure hoses plus 1.5 m yellow hose
  • 1×R134a high/low coupler set
  • 1×Regional power cord
  • 1×Bedienungsanleitung
AUTOOL LM806 recovery machine with red and blue couplers, power cord, red, blue and yellow hoses and user manual
LM806 package contents. Confirm the plug type against the unit nameplate.

Anwendung

  1. Confirm R134a and scopeIdentify the refrigerant, isolate contamination and get the vehicle charge, oil and permitted-flushing procedure.
  2. Inspect the stationKeep the unit level, check scales, containers, tank and hoses, and use grounded power matching the nameplate.
  3. Connect the couplersClean the service ports, secure the high/low couplers and keep hoses away from hot or moving parts.
  4. Verify vehicle dataUse the database as a starting point, then confirm refrigerant mass, oil type and quantity from the vehicle or OEM source.
  5. Recover and account for oilRecover R134a into the working tank and record the oil removed.
  6. Evacuate and holdEvacuate after recovery; stop and diagnose the connection or system if the vacuum-hold check fails.
  7. Flush, add oil and rechargeFlush only permitted lines, then add the measured OEM-specified oil and R134a charge.
  8. Verify and disconnectReview pressures and cooling, print the record and close the couplers before disconnecting.

Setup, oil handling, flushing and troubleshooting: LM806 user manual (PDF).

Good to Know

Caution
  • Never connect the LM806 to R1234yf, mixed, unidentified or any other refrigerant, and never route contaminated refrigerant into the working tank.
  • Never fill the tank beyond 80% of its effective capacity.
  • Use grounded power matching the nameplate, avoid extension cords and disconnect power before maintenance.
  • Do not use compressed air in the refrigerant circuit for leak testing.
  • Wear eye protection and rubber gloves, and provide mechanical ventilation of at least four air changes per hour.
  • On hybrid and electric vehicles, follow the exact OEM oil requirement and every high-voltage safety step.
Care
  • At first setup, remove the transport restraints, keep the scales unobstructed and zero only an empty tank.
  • Replace the drying filter at its service-life prompt.
  • Replace vacuum-pump oil after 600 operating minutes, or sooner if it is visibly degraded.
  • Stay with the machine during the cycle and verify the final result; only qualified personnel should operate it.

You may also like

Select specifications

Offers

  • 10%
    10% off AUTOOL & MRCARTOOLBrands: AUTOOL, MRCARTOOL, FXTUL, CMTOOL, DUOYICode: AB10OFF

Offers are applied at checkout according to the store rules.

Delivery

Ships in 1-3 business days

Warehouses

  • CN-Lager
  • DE-Lager
  • US-Lager

Choose the warehouse in the specifications.

Payment methods

  • Kredit-/DebitkarteVisaMastercardAmerican Express
  • PayPalPayPal
  • LinkLink
  • iDEAL | WeroiDEAL | Wero
  • BancontactBancontact
  • EPSEPS
  • Przelewy24Przelewy24

Available methods may vary by currency and billing country; the final list is shown at checkout.

Service

  • Sichere Kasse

    Zahlungen werden über eine verschlüsselte Verbindung abgewickelt.

  • After-Sales-Support

    Kontaktieren Sie uns bei Fragen zur Installation oder Verwendung.

Specifications

Brand
AUTOOL
SKU
AUTOOL-80430
Dimensions
n. v.
Applicable Refrigerants
R134a only
Recovery Speed
>350 g/min
Charging Speed
>800 g/min
Vacuum Pump Flow Rate
60 L/min
Display
10.1-inch touch screen
Electronic Scales
4: working tank ±10 g; PAG/POE/waste oil ±5 g
Tankvolumen
18 kg working tank (not exceeding 80% of effective capacity)
Oil Bottles
3 (2 new oil + 1 waste oil), automatic oil injection
Funktionen
Recovery, recycling, vacuum, charging, line flushing, pressure hold check
Database
Editable vehicle database for 61 brands
Records
VIN entry, thermal printing, operation record query
Sprachen
5 languages
Kompatibilität
R134a gasoline, hybrid and electric vehicles (per OEM refrigerant oil and high-voltage procedures)
Software-Updates
Editable 61-brand database; 5 languages

Bewertung schreiben

AUTOOL LM806 R134a A/C Recovery Machine with Recharge & Line Flushing
Overall rating *
What stood out?optional, up to 3
Add photos0 / 5
JPG, PNG or WebP, up to 5 MB each.

Bewertungen werden vor der Veröffentlichung geprüft. „Verifizierter Kauf“ wird automatisch hinzugefügt, wenn Ihre E-Mail-Adresse mit einer Bestellung übereinstimmt.

AUTOOL LM806 R134a Recovery, Recharge & A/C Line Flushing Workstation
AUTOOL LM806 R134a A/C Recovery Machine with Recharge & Line Flushing

US$4,999.00

Ausführung wählen Dieses Produkt weist mehrere Varianten auf. Die Optionen können auf der Produktseite gewählt werden