Read Refrigerant Pressure, Temperature and Vacuum on One Digital Gauge
The L202 digital refrigerant gauge uses a high-precision pressure sensor and a built-in database of 90 refrigerants to show pressure and the matching refrigerant temperature in real time, for installing and servicing automotive and refrigeration systems.
- 3 Working Modes
- Pressure Leak Test
- Adjustable Brightness
- Hanging Hook
Hauptmerkmale
-
Refrigerant Measurement Mode
For charging a system with refrigerant, with real-time pressure, temperature and refrigerant type on screen.
-
Vacuum Measurement Mode
For evacuating a system, showing the current vacuum pressure and the percentage of vacuum.
-
Leak Detection Mode
Checks a system for pressure leaks, showing the current pressure, leak pressure and work time.
-
Rotary Valve Control
A rotary switch with a 90-degree limit turns the valve between ON and OFF.
-
Adjustable Screen Brightness
Short-press the power key to change the display brightness.
-
Wide Range of Uses
Automobile and household air conditioning, cold storage and refrigeration equipment.
Highlights

Three Modes
Refrigerant, vacuum and leak detection screens.

Leak Test Readout
Pressure, leak pressure and elapsed time on one screen.

Controls and Connections
Four function keys, inlet and outlet connections, battery cover and hook.
More Specifications
| Test range | 0 kPa to 6000 kPa |
|---|---|
| Auflösung | 1 kPa |
| Accuracy | ±0.5% |
| Overload | 10 MPa |
| Operating temperature | -20°C to 60°C |
| Auto power-off | 10 min |
Model Comparison
| L202 | L205 | L302 | L505 | |
|---|---|---|---|---|
| Refrigerants | 90 | 92 | 90 | 95 |
| Pressure units | kPa, bar, psi, inHg, kgf/cm² | kPa, MPa, bar, inHg, psi | kPa, bar, psi, inHg, kgf/cm² | kPa, bar, psi, inHg, kgf/cm² |
| Dual pressure test | No | No | Yes | Yes |
| Dual temperature test | No | No | Yes | Yes |
| Refrigerant sight window | No | No | No | Yes |
| Pressure leak test | Yes | Yes | Yes | Yes |
| Product size | 150 × 90 × 60 mm | 165 × 113 × 60 mm | 170 × 170 × 60 mm | 210 × 110 × 40 mm |
What’s in the Box
- L202 digital gauge
- Bedienungsanleitung

Setup and operation: L202/L302 user manual (PDF).
Anwendung
- Attach the hoseConnect the hose securely to the low-pressure pipe.
- Connect the vacuum pumpConnect the vacuum machine to the right port and make sure it is sealed.
- Open the low-pressure valveCarefully open the low-pressure valve, using the right tools to avoid damage.
- EvacuateRun the vacuum pump until it reaches a complete vacuum.
- Connect the refrigerantConnect the service hose tightly to the refrigerant canister.
- Run the A/CStart the engine and set the air conditioner to maximum so the refrigerant circulates.
- Check and adjustConfirm the gauge is in the correct mode and adjust as needed.
Good to Know
Care
- Keep the gauge and screen clean; wash the case and connectors with a slightly alkaline detergent or soapy water.
- Check the gauge regularly to confirm its accuracy.
- Handle gently to prevent shocks and falls.
- Close all knobs after use.
- Plug the connectors when not in use, and clean or replace refrigerant hoses regularly to remove dirt from the valves.