Specifications

BrandAUTOOL
SKUAUTOOL-59103
Working PrincipleLow Oxygen Combustion
EingangsspannungDC 12V vehicle battery
Output Pressure and Flow<10 psi, <5 L/min (fixed output, not adjustable)
Air SupplyBuilt-in air pump
Smoke Output TimeApprox. 5 seconds
Test Oil Volume10–15 mL (baby oil/liquid paraffin)
Power50W rated
Weight and DimensionsMain unit 1.6 kg; 180mm*102mm*143mm
BetriebstemperaturMinimum -20°C; overheat protection at 75°C
Continuous OperationNo more than 8 minutes
IndicatorsPower/fault indicator lights (no pressure gauge)
KompatibilitätEVAP, vacuum, intake/exhaust, crankcase, oil seals, intercooler, fuel tank, radiator, low-pressure turbo and other low-pressure systems

Details

Find Low-Pressure Leaks with Smoke, No Shop Air Needed

The SDT100 runs from a 12 V vehicle battery and uses its built-in pump to push visible smoke through EVAP, vacuum, intake, exhaust, crankcase and other low-pressure systems. Output is fixed and it cannot pressure-test an A/C system directly. Testing oil is not included.

  • Built-In Air Pump
  • Smoke in About 5 s
  • 12 V Battery Powered
  • Overheat Protection
  • Fault Indicator

Hauptmerkmale

  1. EVAP and Vacuum Leak Detection

    Also checks intake and exhaust systems, crankcases, oil seals, intercooler air paths, fuel and coolant tanks, line fittings and low-pressure turbo systems.

  2. Built-In Air Pump

    No separate compressor or pump is needed, which shortens setup.

  3. Overheat and Low-Temperature Protection

    Protection stops operation automatically when needed.

  4. Grouped Controls

    Smoke switch, power and alarm indicators, oil filler, smoke output, power socket and handle sit in one compact layout.

Model Comparison

SDT60 SDT100 SDT102
Rated output flow <5 L/min <5 L/min >6 L/min
Pressure gauge Yes No Yes
Fault indicator light No Yes Yes
Rated power 50 W 50 W 48 W

What’s in the Box

  • SDT100 smoke leak detector
  • 12 V battery clamp cable
  • Smoke output hose
  • Cone adapter, red connector, thin hose and airbag adapter
  • Empty testing oil bottle
  • Bedienungsanleitung

Anwendung

  1. Add testing oilFill with baby oil or liquid paraffin; do not overfill.
  2. Connect the test lineDisconnect the line to be tested and connect it to the detector, hanging the unit if needed.
  3. Connect 12 V powerClamp to the battery and switch the detector on.
  4. Locate leaksThe line fills with smoke in about 30 seconds; look for escaping smoke, using a headlamp if necessary.
  5. Repair and retestRepair the confirmed leak and repeat the same test; continue with the vehicle procedure if no smoke is visible.

Smoke generation, test-oil handling and troubleshooting: SDT100 user manual (PDF)

Good to Know

Caution
  • Testing oil is not included; use dedicated smoke oil, liquid paraffin or baby oil.
  • Not for direct A/C pressure testing; smoke can only aid inspection of an isolated, separately pressurized A/C line section.
  • Never refill testing oil while the unit is running.
  • The metal housing gets hot in use; avoid touching it and let the unit cool before restarting after overheat shutdown.
Care
  • Refill only when the smoke becomes thin, and drain remaining oil before adding fresh oil.
  • The fault indicator shows unit status, not pressure or airflow.

You may also like

Select specifications

Offers

  • 10%
    10% off AUTOOL & MRCARTOOLBrands: AUTOOL, MRCARTOOL, FXTUL, CMTOOL, DUOYICode: AB10OFF

Offers are applied at checkout according to the store rules.

Delivery

Ships in 1-3 business days

Warehouses

  • CN-Lager
  • DE-Lager
  • UK-Lager
  • US-Lager

Choose the warehouse in the specifications.

Payment methods

  • Kredit-/DebitkarteVisaMastercardAmerican Express
  • PayPalPayPal
  • LinkLink
  • iDEAL | WeroiDEAL | Wero
  • BancontactBancontact
  • EPSEPS
  • Przelewy24Przelewy24

Available methods may vary by currency and billing country; the final list is shown at checkout.

Service

  • Sichere Kasse

    Zahlungen werden über eine verschlüsselte Verbindung abgewickelt.

  • After-Sales-Support

    Kontaktieren Sie uns bei Fragen zur Installation oder Verwendung.

Specifications

Brand
AUTOOL
SKU
AUTOOL-59103
Working Principle
Low Oxygen Combustion
Eingangsspannung
DC 12V vehicle battery
Output Pressure and Flow
<10 psi, <5 L/min (fixed output, not adjustable)
Air Supply
Built-in air pump
Smoke Output Time
Approx. 5 seconds
Test Oil Volume
10–15 mL (baby oil/liquid paraffin)
Power
50W rated
Weight and Dimensions
Main unit 1.6 kg; 180mm*102mm*143mm
Betriebstemperatur
Minimum -20°C; overheat protection at 75°C
Continuous Operation
No more than 8 minutes
Indicators
Power/fault indicator lights (no pressure gauge)
Kompatibilität
EVAP, vacuum, intake/exhaust, crankcase, oil seals, intercooler, fuel tank, radiator, low-pressure turbo and other low-pressure systems

Bewertung schreiben

AUTOOL SDT100 Automotive Smoke Leak Detector with Built-In Air Pump
Overall rating *
What stood out?optional, up to 3
Add photos0 / 5
JPG, PNG or WebP, up to 5 MB each.

Bewertungen werden vor der Veröffentlichung geprüft. „Verifizierter Kauf“ wird automatisch hinzugefügt, wenn Ihre E-Mail-Adresse mit einer Bestellung übereinstimmt.

AUTOOL SDT100 Automotive Smoke Leak Detector with Built-In Air Pump
AUTOOL SDT100 Automotive Smoke Leak Detector with Built-In Air Pump

US$65.00

Ausführung wählen Dieses Produkt weist mehrere Varianten auf. Die Optionen können auf der Produktseite gewählt werden