Specifications

BrandAUTOOL
SKUAUTOOL-80764
Working PrincipleLow Oxygen Combustion
Power SupplyDC 12V / 5A, rated 65W
Output Pressure<15 psi
Flow Rate<6 L/min (no flow adjustment knob)
ModesAir Mode / Smoke Mode
Air SupplyBuilt-in air pump, no external compressed air required
Pressure GaugeMechanical pressure gauge
Oil Fill Volume10ml
Smoke Output TimeApprox. 5 seconds
SchutzOverheat shutdown above 75°C
Weight and DimensionsNet weight 3.2kg; 250mm*160mm*165mm
KompatibilitätAutomotive intake, EVAP and other line systems (set pressure per OEM procedure)

Details

Check Pressure with Air, Then Trace the Leak with Smoke

The SML310 runs an air-only stage so you can watch the gauge on the connected test volume, then switches to smoke to show the escape path. Its built-in pump runs from a 12 V supply, so no shop air is needed. Set test pressure from the vehicle or component procedure.

  • Air Mode / Smoke Mode
  • Built-In Pump
  • Mechanical Pressure Gauge
  • Smoke in About 5 Seconds
  • Overheat Shutdown

Hauptmerkmale

  1. Separate Air and Smoke Modes

    Use the air stage to observe pressure behavior, then switch to smoke for visual localization.

  2. Built-In Air Pump

    The internal pump supplies the test airflow, so routine setup does not need a separate compressor.

  3. Pressure Gauge Feedback

    Watch the reading while the test volume fills, then use smoke to inspect an unstable or falling reading.

  4. Fast Smoke Start

    Smoke starts in about five seconds once the prepared system is connected and the mode is activated.

  5. Temperature Protection

    Operation stops when the unit reaches its protection condition; let it cool before further use.

Anwendung

  1. Confirm the procedureIdentify the target system, permitted pressure, access point, valve state and openings to seal.
  2. Prepare the machineInspect the power lead, hose and adapters, and add or confirm only the smoke oil the manual specifies.
  3. Connect and isolateMake a leak-free connection with the correct adapter and isolate normal escape paths per the vehicle procedure.
  4. Run Air ModeObserve the pressure gauge under the selected test conditions.
  5. Inspect with smokeSwitch to Smoke Mode, let the volume fill and check joints, hoses and seals for escaping smoke.
  6. Repair and retestRepair the confirmed leak, repeat the same test and continue diagnosis if the result is inconclusive.

Air and smoke modes, pressure checks and troubleshooting: SML310 user manual (PDF).

Good to Know

Caution
  • The machine’s output rating is not a safe pressure for every system; use the OEM procedure and the lowest appropriate setting, especially on EVAP systems.
  • Use only the smoke fluid the manual specifies; never water, viscous or corrosive liquids.
  • Work in a dry, ventilated area away from flame and heat, wear eye and hand protection, and keep smoke away from sensitive electronic parts.
  • Do not operate with damaged power leads, hoses or adapters; clean an opening before inserting an inflatable plug so sharp edges do not puncture it.
Care
  • Connect to a stable vehicle-battery supply.
  • Package contents can vary by order; confirm the included accessories before checkout.

FAQ

What if no smoke is visible?

Verify smoke delivery, access, isolation, adapter sealing and valve state, then continue with functional diagnosis; blockages, intermittent and non-leak faults may not produce visible smoke.

Does a visible leak guarantee the whole repair?

It identifies an area to inspect and confirm. Repair the verified problem, repeat the test and complete any required vehicle checks.

You may also like

Select specifications

Delivery

Shipping calculated at checkout

Warehouses

  • CN-Lager

Choose the warehouse in the specifications.

Service

  • Sichere Kasse

    Zahlungen werden über eine verschlüsselte Verbindung abgewickelt.

  • After-Sales-Support

    Kontaktieren Sie uns bei Fragen zur Installation oder Verwendung.

Specifications

Brand
AUTOOL
SKU
AUTOOL-80764
Working Principle
Low Oxygen Combustion
Power Supply
DC 12V / 5A, rated 65W
Output Pressure
<15 psi
Flow Rate
<6 L/min (no flow adjustment knob)
Modes
Air Mode / Smoke Mode
Air Supply
Built-in air pump, no external compressed air required
Pressure Gauge
Mechanical pressure gauge
Oil Fill Volume
10ml
Smoke Output Time
Approx. 5 seconds
Schutz
Overheat shutdown above 75°C
Weight and Dimensions
Net weight 3.2kg; 250mm*160mm*165mm
Kompatibilität
Automotive intake, EVAP and other line systems (set pressure per OEM procedure)

Bewertung schreiben

AUTOOL SML310 Automotive-Rauch-Lecksuchgerät mit mechanischem Manometer
Overall rating *
What stood out?optional, up to 3
Add photos0 / 5
JPG, PNG or WebP, up to 5 MB each.

Bewertungen werden vor der Veröffentlichung geprüft. „Verifizierter Kauf“ wird automatisch hinzugefügt, wenn Ihre E-Mail-Adresse mit einer Bestellung übereinstimmt.

AUTOOL SML310 Automotive-Rauch-Lecksuchgerät mit mechanischem Manometer
AUTOOL SML310 Automotive-Rauch-Lecksuchgerät mit mechanischem Manometer

Ursprünglicher Preis war: US$499.00Aktueller Preis ist: US$269.00.

Ausführung wählen Dieses Produkt weist mehrere Varianten auf. Die Optionen können auf der Produktseite gewählt werden