Specifications

BrandAUTOOL
SKUAUTOOL-29068
Pressure Range-101 kPa–6 MPa (gauge limit 10 MPa)
MeasurementSimultaneous high/low pressure, dual T1/T2 temperature (clamps sold separately)
CalculationSuperheat SH / subcooling SC
ModesRelative vacuum, timed pressure hold (ΔP), charging assist
Refrigerant Database89 NIST refrigerants per manual (actual version prevails)
UnitskPa, MPa, bar, inHg, PSI; °C/°F
DisplayLarge backlit LCD
ConnectorStandard 1/4 in, with sight glass and high/low valves
Power Supply4 × 1.5V AA/LR6 batteries
Weight950 g
CompatibilityRefrigerant pressure testing and service for automotive AC and refrigeration systems (AC, cold storage, etc.)

Details

Read High and Low Side Together, with Superheat and Subcooling Ready

The LM120+ digital manifold reads high- and low-side pressure at once and controls refrigerant flow with dedicated valves and a sight glass. Add compatible wired temperature clamps, sold separately, for T1/T2 readings and SH/SC calculations.

  • Dual Pressure Readings
  • T1/T2 with Optional Clamps
  • Superheat / Subcooling
  • Vacuum & Pressure Hold
  • Charging Assist

Key Features

  1. Simultaneous High/Low Pressure

    Read both sides during A/C and refrigeration service work.

  2. Dual Temperature Inputs

    Shows real-time T1 and T2 when compatible clamp probes are connected and fully seated on the pipes.

  3. Superheat and Subcooling

    Calculated after you select the correct refrigerant and attach stable temperature probes.

  4. Relative-Vacuum Mode

    Monitors pressure during an approved evacuation procedure, with leak time recording.

  5. Timed Pressure Retention

    Shows initial and current pressure, ΔP and elapsed time for system-tightness checks.

  6. Charging Assistance

    Use the valves, sight glass and selected refrigerant data within the equipment’s procedure.

  7. Handheld Construction

    Engineering-plastic body with non-slip silicone, long-life valves and a foldable hook.

More Specifications

Standard hose working pressure 600 PSI (about 4.13 MPa)
Standard hose limit pressure 3000 PSI (about 20.68 MPa)

Model Comparison

LM120 LM120+ LM150 LM160
Focus Core digital manifold Three-color hose and clamp support Larger refrigerant database Program control, 8 languages
Temperature clamps Confirm package Supported, not included Two shown in package Two shown in package

What’s in the Box

  • LM120+ main unit
  • Red, blue and yellow hose set
  • Adapters and couplers (exact items depend on the package)
  • Storage case
  • User manual

How to Use

  1. Identify the refrigerantSelect the refrigerant confirmed by the vehicle or equipment information.
  2. Check kit and ratingsConfirm probes, batteries and the separate gauge, hose and system ratings.
  3. Inspect, zero and connectClose the valves, inspect fittings and hoses, choose refrigerant and units, zero if needed, then connect.
  4. Measure or serviceUse pressure, vacuum or retention mode; attach both clamps firmly for T1/T2 or SH/SC.
  5. Close and reviewFollow the manual’s valve and disconnect sequence and interpret results against the system specification.

Specifications, refrigerant filling, vacuum and leak testing: LM120 / LM120+ user manual (PDF)

Good to Know

Caution
  • Temperature clamps are not included; T1/T2 and SH/SC need compatible wired clamps bought separately.
  • Work within the lowest rating of the system, gauge and hose; the hose working pressure is lower than the gauge limit.
  • Replace damaged hoses, seals and fittings before connecting.
  • The gauge does not identify refrigerant or locate leaks; use a reliable identification and an approved leak-location method.
  • Batteries may not be included; confirm for your order.
Care
  • Wear protective equipment and work in a well-ventilated area.
  • Keep the instrument away from hot, humid, flammable, explosive or strong-EMF environments, and do not modify its circuit.

You may also like

Select specifications

Delivery

Shipping calculated at checkout

Warehouses

  • CN Warehouse
  • DE Warehouse
  • UK Warehouse
  • US Warehouse

Choose the warehouse in the specifications.

Service

  • Secure checkout

    Payments are processed over an encrypted connection.

  • After-sales support

    Contact us for installation or usage questions.

Specifications

Brand
AUTOOL
SKU
AUTOOL-29068
Pressure Range
-101 kPa–6 MPa (gauge limit 10 MPa)
Measurement
Simultaneous high/low pressure, dual T1/T2 temperature (clamps sold separately)
Calculation
Superheat SH / subcooling SC
Modes
Relative vacuum, timed pressure hold (ΔP), charging assist
Refrigerant Database
89 NIST refrigerants per manual (actual version prevails)
Units
kPa, MPa, bar, inHg, PSI; °C/°F
Display
Large backlit LCD
Connector
Standard 1/4 in, with sight glass and high/low valves
Power Supply
4 × 1.5V AA/LR6 batteries
Weight
950 g
Compatibility
Refrigerant pressure testing and service for automotive AC and refrigeration systems (AC, cold storage, etc.)

Write a review

AUTOOL LM120+ Digital Manifold Gauge with T1/T2 Clamp Inputs
Overall rating *
What stood out?optional, up to 3
Add photos0 / 5
JPG, PNG or WebP, up to 5 MB each.

Reviews are checked before they appear. Verified Purchase is added automatically when your email matches an order.

AUTOOL LM120+ Digital Manifold Gauge with T1/T2 Clamp Inputs
AUTOOL LM120+ Digital Manifold Gauge with T1/T2 Clamp Inputs

US$149.00

Seleccionar opciones Este producto tiene múltiples variantes. Las opciones se pueden elegir en la página de producto