AUTOBOSSautoboss.com
Source: https://autoboss.com/es/es/product/autool-lm55-pipe-clamp-temperature-meter-with-waveform-recording/
0

Reseñas

Todavía no hay reseñasSé el primero en compartir tu experiencia con este producto.

Specifications

BrandAUTOOL
SKUAUTOOL-41592
Measuring ObjectPipe clamp contact temperature measurement, pipe diameter <40 mm
Measuring Range-50°C to 260°C (below 150°C recommended for daily use)
Waveform Storage8 sets, up to 150 s each, pause/review
Pantalla0.96-inch color TFT-LCD 80 RGB×160, brightness adjustable 0-100
Units / Languages°C/°F switchable; Chinese/English
Power Supply3×AAA batteries (4.5V)
HousingPA6-GF45
Dimensions178 × 100 mm
CompatibilidadPipe temperature measurement for HVAC, refrigeration and automotive AC lines; does not measure pressure

Details

Watch Pipe Temperature Change as a Live Curve

Clamp the LM55 onto a pipe under 40 mm to read live temperature and follow heating or cooling on a real-time curve during HVAC, refrigeration and automotive A/C work. It reads temperature only, not pressure.

  • Pipes Under 40 mm
  • Live Temperature Curve
  • 8 × 150 s Records
  • Pause and Resume
  • °C / °F

Key Features

  1. Live Reading

    Read the current pipe temperature once the clamp has stable contact.

  2. Real-Time Waveform

    Follow the direction and rate of change on a temperature/time curve.

  3. Saved Records

    Store and browse waveform sets for later comparison; recording stops with an alert when storage is full.

  4. Pause and Resume

    Press Enter to pause and resume a live recording.

  5. Color Display

    Shows live temperature, waveforms, saved records and settings, with adjustable backlight.

Model Comparison

LM55 LM70 LM120+
Primary task Single-pipe temperature trend Dual-pressure manifold with two pipe temperatures Manifold workflow with clamp support
Pressure measurement No Yes Yes

What’s in the Box

  • LM55 pipe-clamp thermometer
  • User manual
  • Retail box
AUTOOL LM55 digital temperature clamp with its retail box and user manual
LM55 package contents.

How to Use

  1. Choose the pipePick a clean, stable pipe under 40 mm and avoid unsafe high-temperature points.
  2. Power onInsert three AAA batteries correctly and hold Enter for about two seconds.
  3. Clamp with full contactSeat the sensor firmly without forcing the jaw onto an oversized or irregular surface.
  4. Read or recordRead the current value or monitor the curve, pausing and resuming as needed.
  5. CompareReview stored records taken under comparable conditions.

Specifications, operation, buttons, display and maintenance: LM55 user manual (PDF).

Good to Know

Caution
  • Keep routine pipe measurements below 150°C; the wider instrument range is a specification, not a safe application limit.
  • It cannot diagnose an A/C fault by itself; combine the trend with pressure, airflow and equipment data.
Care
  • If a curve jumps, check clamp contact, pipe surface and movement before blaming the system.
  • Store dry, away from heat, humidity, corrosive liquids and poorly ventilated places.

You may also like

Select specifications

Offers

  • 10%
    10% off AUTOOL & MRCARTOOLBrands: AUTOOL, MRCARTOOL, FXTUL, CMTOOL, DUOYICode: AB10OFF

Offers are applied at checkout according to the store rules.

Delivery

Ships in 1-3 business days

Warehouses

  • CN Warehouse
  • DE Warehouse
  • UK Warehouse
  • US Warehouse

Choose the warehouse in the specifications.

Payment methods

  • Tarjeta de Crédito / DébitoVisaMastercardAmerican Express
  • PayPalPayPal
  • LinkLink
  • iDEAL | WeroiDEAL | Wero
  • BancontactBancontact
  • EPSEPS
  • Przelewy24Przelewy24

Available methods may vary by currency and billing country; the final list is shown at checkout.

Service

  • Secure checkout

    Payments are processed over an encrypted connection.

  • After-sales support

    Contact us for installation or usage questions.

Specifications

Brand
AUTOOL
SKU
AUTOOL-41592
Measuring Object
Pipe clamp contact temperature measurement, pipe diameter <40 mm
Measuring Range
-50°C to 260°C (below 150°C recommended for daily use)
Waveform Storage
8 sets, up to 150 s each, pause/review
Pantalla
0.96-inch color TFT-LCD 80 RGB×160, brightness adjustable 0-100
Units / Languages
°C/°F switchable; Chinese/English
Power Supply
3×AAA batteries (4.5V)
Housing
PA6-GF45
Dimensions
178 × 100 mm
Compatibilidad
Pipe temperature measurement for HVAC, refrigeration and automotive AC lines; does not measure pressure

Escribe una reseña

AUTOOL LM55 Pipe Clamp Thermometer with Waveform Recording
Overall rating *
What stood out?optional, up to 3
Add photos0 / 5
JPG, PNG or WebP, up to 5 MB each.

Reviews are checked before they appear. Verified Purchase is added automatically when your email matches an order.

AUTOOL LM55 Pipe Clamp Temperature Meter with Waveform Recording
AUTOOL LM55 Pipe Clamp Thermometer with Waveform Recording

US$45.00

Seleccionar opciones Este producto tiene múltiples variantes. Las opciones se pueden elegir en la página de producto